Fluke 1587 Insulation Multimeter with K-Type Thermocouple

Update Terakhir
:
16 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
36 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 1587 Insulation Multimeter With K-Type Thermocouple

Fluke 1587 Insulation Multimeter with K-Type Thermocouple Insulation test: 0.01 Mohm to 2 Gohm Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V Live circuit detection prevents insulation test if voltage Large display with backlight 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/ DC voltage, DC milliVolts, AC/ DC milliamps, Resistance ( W) , Continuity Auto power off to save battery power CAT III 1000 V, CAT IV 600 V measurement category Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work Rugged, utility hard case allows you to bring everything you need for the job Electrical Specifications DC Voltage Maximum Voltage: 1000V Accuracy ( 1577) : ± ( 0.2% + 2) Accuracy ( 1587) : ± ( 0.09% + 2) Maximum Resolution: 0.001V AC Voltage Maximum Voltage: 1000V Accuracy ( 1577) : ± ( 2% + 3) Accuracy ( 1587) : ± ( 2% + 3) AC Bandwidth: ( 1587 Only) 5kHz; with low pass filter; 3db @ 800 Hz Maximum Resolution: 0.001V DC Current Maximum Amps: 400mA Amps Accuracy ( 1577) : ± ( 1.0% + 2) Amps Accuracy ( 1587) : ± ( 0.2% + 2) Maximum Resolution: 0.01 mA AC Current Maximum Amps: 400mA Amps Accuracy ( 1577) : 1kHz bandwidth ± ( 2.0% + 2) Amps Accuracy ( 1587) : 1kHz bandwidth ± ( 1.5% + 2) Maximum Resolution: 0.01 mA Resistance Maximum Resistance: 50M© Accuracy ( 1577) : ± ( 1.2% + 2) Accuracy ( 1587) : ± ( 0.9% + 2) Maximum Resolution: 0.1© Capacitance ( 1587 only) Maximum Capacitance: 9, 999 µ F Accuracy: ± ( 1.2% + 2) Maximum Resolution: 1 nF Frequency ( 1587 only) Maximum Frequency: ± ( 0.1% + 1) Accuracy: ± ( 0.1% + 1) Maximum Resolution: 1 nF Temperature Measurement ( 1587 only) Range: -40° C to 537° C -40° F to 998° F Resolution 0.1° C 0.1° F Accuracy ± ( % of Rdg+ Digits) ± ( 1% + 10 counts) ± ( 1% + 18 counts) Diode Test ( 1587 only) Range: 6 V Resolution: 1 mV Accuracy: ± ( 2 % + 1) Included Accessories 1 - Remote Probe 1 - Test lead set 1 - Set of Alligator Clips 1 - K-type Thermocouple Probe 1 - Hard Case 1 - Quick Reference Guide 1 - CD Rom with Manual 1 - AA Alkaline Batteries INDONESIA INSTRUMENT BUANA SURVEY JAKARTA 0217321129 JL. MUCHTAR RAYA NO. 1D, KREO - CILEDUG 15156 CP : IRFAN 081908101888 T : 0217321129 F : 0217302811 M : 081908101888
Tampilkan Lebih Banyak